PowerFlex 40 and 400 Drive Control Logic

PowerFlex 40 Drive Control Logic Chart

Cabinet Hardmount

“A” control, “B” control, “V” Control and EDC/Netmaster Control

H – Signal Voltage High (approximately 24V DC)

 

 

 

 

 

 

 

 

 

0 = No signal received

 

 

L – Signal Voltage Low (less than 1V DC)

 

 

 

 

 

 

 

 

 

1 = Signal received

 

 

 

 

Digital

Digital

Digital

Stop

Rev

Fwd

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In 3

In 2

In 1

 

Digital Input

Control Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status – Parameter

Status – Parameter

DC Volt Meter Red Probe Terminal Location

07

06

05

01

03

02

 

 

d014

 

 

d013

 

DC Volt Meter Black Probe Terminal Location

04

04

04

04

04

04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

Terminal

Terminal

Terminal

Terminal

Terminal

Terminal

*DigitalIn 4

 

InDigital3 (SW3)

InDigital2 (SW2)

InDigital1 (SW1)

TransDB On

Stop

(STR)Rev

(STF)Fwd

Action

Preset

#07

#06

#05

#01

#03

#02

 

 

 

 

 

 

 

 

 

 

Parameter #

(SW3)

(SW2)

(SW1)

(Stop)

(STR)

(STF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Idle

N/A

H

H

H

L/H

H

H

0

 

0

0

0

0

0/1

0

0

1/2 Wash Speed Forward

71

H

H

L

L

H

L

*1

 

0

0

1

0

1

0

1

1/2 Wash Speed Reverse

71

H

H

L

L

L

H

0

 

0

0

1

0

1

1

0

Wash Speed Forward

72

H

L

H

L

H

L

*1

 

0

1

0

0

1

0

1

Wash Speed Reverse

72

H

L

H

L

L

H

0

 

0

1

0

0

1

1

0

Distribution Speed

74

L

H

H

L

H

L

*1

 

1

0

0

0

1

0

1

Spin 1

73

H

L

L

L

H

L

*1

 

0

1

1

0

1

0

1

Spin 2

76

L

L

H

L

H

L

*1

 

1

1

0

0

1

0

1

Spin 3

75

L

H

L

L

H

L

*1

 

1

0

1

0

1

0

1

*If digital in 4 is wired to the Forward Input terminal #02, this input will be a “1” whenever the drive receives a forward command. Disregard otherwise.

Cabinet Hardmount

Galaxy control, Quantum control and UniMac Software Control

H – Signal Voltage High (approximately 24V DC)

 

 

 

 

 

 

 

 

 

0 = No signal received

 

 

L – Signal Voltage Low (less than 1V DC)

 

 

 

 

 

 

 

 

 

1 = Signal received

 

 

 

 

Digital

Digital

Digital

Stop

Rev

Fwd

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In 3

In 2

In 1

 

Digital Input

 

Control Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status – Parameter

Status – Parameter

DC Volt Meter Red Probe Terminal Location

07

06

05

01

03

02

 

 

d014

 

 

d013

 

DC Volt Meter Black Probe Terminal Location

04

04

04

04

04

04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

Terminal

Terminal

Terminal

Terminal

Terminal

Terminal

*DigitalIn 4

 

DigitalIn 3

DigitalIn 2

 

DigitalIn 1

TransDB On

Stop

Rev

Fwd

 

 

 

 

 

 

 

 

 

 

 

Action

Preset

#07

#06

#05

#01

#03

#02

 

 

 

 

 

 

 

 

 

 

 

Parameter #

(SW3)

(SW2)

(SW1)

(Stop)

(STR)

(STF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Idle

N/A

H

H

H

L/ H

H

H

0

 

0

0

 

0

0

0/1

0

0

Reduced Wash speed (ccw)

70

H

H

H

L

L

H

0

 

0

0

 

0

0

1

1

0

Reduced Wash Speed (cw)

70

H

H

H

L

H

L

0

 

0

0

 

0

0

1

0

1

Wash Speed (ccw)

72

H

L

H

L

L

H

0

 

0

1

 

0

0

1

1

0

Wash Speed (cw)

72

H

L

H

L

H

L

0

 

0

1

 

0

0

1

0

1

Distribution Speed 1 (ccw)

71

H

H

L

L

L

H

0

 

0

0

 

1

0

1

1

0

Extract Speed 1 (ccw)

76

L

L

H

L

L

H

0

 

1

1

 

0

0

1

1

0

Extract Speed 2 (ccw)

75

L

H

L

L

L

H

0

 

1

0

 

1

0

1

1

0

Extract Speed 3 (ccw)

73

H

L

L

L

L

H

0

 

0

1

 

1

0

1

1

0

Extract Speed 4 (ccw)

77

L

L

L

L

L

H

0

 

1

1

 

1

0

1

1

0

Extract Speed 5 (ccw)

74

L

H

H

L

L

H

0

 

1

0

 

0

0

1

1

0

Table 8

14