PowerFlex 40 and 400 Drive Control Logic

Pocket Hardmount

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WE-6 control - Design 6, 7 and 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H – Signal Voltage High (approximately 24V DC)

 

 

 

 

 

 

 

 

 

0 = No signal received

 

 

L – Signal Voltage Low (less than 1V DC)

 

 

 

 

 

 

 

 

 

1 = Signal received

 

 

 

 

Digital

Digital

Digital

Stop

Rev

Fwd

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In 3

In 2

In 1

 

Digital Input

Control Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status – Parameter

Status – Parameter

DC Volt Meter Red Probe Terminal Location

07

06

05

01

03

02

 

 

d014

 

 

d013

 

DC Volt Meter Black Probe Terminal Location

04

04

04

04

04

04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

Terminal

Terminal

Terminal

Terminal

Terminal

Terminal

*DigitalIn 4

 

DigitalIn 3 (SW3)

DigitalIn 2 (SW2)

DigitalIn 1 (SW1)

TransDB On

Stop

(STR)Rev

(STF)Fwd

Action

Preset

#07

#06

#05

#01

#03

#02

 

 

 

 

 

 

 

 

 

 

Parameter #

(SW3)

(SW2)

(SW1)

(Stop)

(STR)

(STF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Idle

N/A

H

H

H

L/H

H

H

0

 

0

0

0

0

0/1

0

0

1/2 Wash Speed Forward

70

H

H

H

L

H

L

*1

 

0

0

0

0

1

0

1

1/2 Wash Speed Reverse

70

H

H

H

L

L

H

0

 

0

0

0

0

1

1

0

Wash Speed Forward

72

H

L

H

L

H

L

*1

 

0

1

0

0

1

0

1

Wash Speed Reverse

72

H

L

H

L

L

H

0

 

0

1

0

0

1

1

0

Distribution Speed

71

H

H

L

L

H

L

*1

 

0

0

1

0

1

0

1

Medium Extract/Spray Rinse

76

L

L

H

L

H

L

*1

 

1

1

0

0

1

0

1

Extract Speed 1

75

L

H

L

L

H

L

*1

 

1

0

1

0

1

0

1

Extract Speed 2

73

H

L

L

L

H

L

*1

 

0

1

1

0

1

0

1

Extract Speed 3 (default)

77

L

L

L

L

H

L

*1

 

1

1

1

0

1

0

1

Extract Speed 3 (maximum)

74

L

L

H

L

H

L

*1

 

1

0

0

0

1

0

1

*If digital in 4 is wired to the Forward Input terminal #02, this input will be a “1” whenever the drive receives a forward command. Disregard otherwise.

Table 11

F232120

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

17