160 Series Drive Control Logic Chart
Pocket Hardmount - IPH, IP and CP Models
PS40 control
H – Control Voltage High (greater than 10V DC) |
|
|
|
| 0 = No signal received | |||
L – Control Voltage Low (less than 1V DC) |
|
|
|
|
| 1 = Signal received |
| |
| Fwd | Stop | Rev |
|
|
|
|
|
|
| Control Input Status – | ||||||
DC Volt Meter Red Probe Terminal Location | 06 | 08 | 05 |
| ||||
|
| Parameter 12 |
| |||||
DC Volt Meter Black Probe Terminal Location | 03 | 03 | 03 |
|
|
| ||
|
|
|
|
| ||||
| Terminal | Terminal | Terminal |
| UsedNot | STF | Stop | STR |
Action | #06 | #08 | #05 |
|
|
|
|
|
| (STF) | (Stop) | (STR) |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Idle | H | L | H | 0 | 0 | 1 | 0 | |
Wash Speed Forward | L | L | H | 0 | 1 | 1 | 0 | |
Wash Speed Reverse | H | L | L | 0 | 0 | 1 | 1 | |
Distribution Speed | L | L | H | 0 | 1 | 1 | 0 | |
Low Spin Speed | L | L | H | 0 | 1 | 1 | 0 | |
Medium Spin Speed | L | L | H | 0 | 1 | 1 | 0 | |
High Spin Speed | L | L | H | 0 | 1 | 1 | 0 | |
SmartSpin | L | L | L | 0 | 1 | 1 | 1 |
NOTE: These models use analog signals to control speed – refer to parameter #6 (command freq.) and parameter #16 (analog input %) to verify speed input signal.
Table 30