Cabinet Hardmount |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
H – Control Voltage High (approximately 5V DC) |
|
|
|
|
|
|
|
|
| 0 = No Signal Received |
|
| |||||
L – Control Voltage Low (less than 1V DC) |
|
|
|
|
|
|
|
|
| 1 = Signal Received |
|
| |||||
|
|
| SW3 | SW2 | SW1 | Rev | Stop |
| Fwd |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
DC Volt Meter Red Probe Terminal Location |
| 18 | 17 | 16 | 13 | 8 |
| 6 |
| Input Status - Parameter #55 |
| ||||||
DC Volt Meter Black Probe Terminal Location |
| 7 | 7 | 7 | 7 | 7 |
| 7 |
|
|
|
|
|
|
|
| |
| Frequency |
| Terminal | Terminal | Terminal | Terminal | Terminal |
| Terminal | UsedNot | SW3 | SW2 | SW1 | UsedNot | (STR)Rev | Stop | (STF)Fwd |
|
|
|
|
|
|
|
|
|
|
| |||||||
Action | Preset |
| #18 | #17 | #16 | #13 | #8 |
| #6 |
|
|
|
|
|
|
|
|
| Parameter |
| (SW3) | (SW2) | (SW1) | (STR) | (Stop) |
| (STF) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Idle | N/A |
| H | H | H | H | L/H |
| H | 0 | 0 | 0 | 0 | 0 | 0 | 0/1 | 0 |
1/2 Wash Speed Forward | 27 |
| H | H | L | H | L |
| L | 0 | 0 | 0 | 1 | 0 | 0 | 1 | 1 |
1/2 Wash Speed Reverse | 27 |
| H | H | L | L | L |
| H | 0 | 0 | 0 | 1 | 0 | 1 | 1 | 0 |
Wash Speed Forward | 28 |
| H | L | H | H | L |
| L | 0 | 0 | 1 | 0 | 0 | 0 | 1 | 1 |
Wash Speed Reverse | 28 |
| H | L | H | L | L |
| H | 0 | 0 | 1 | 0 | 0 | 1 | 1 | 0 |
Distribution Speed | 73 |
| L | H | H | H | L |
| L | 0 | 1 | 0 | 0 | 0 | 0 | 1 | 1 |
Spin 1 | 29 |
| H | L | L | H | L |
| L | 0 | 0 | 1 | 0 | 0 | 0 | 1 | 1 |
Spin 2 | 75 |
| L | L | H | H | L |
| L | 0 | 1 | 1 | 0 | 0 | 0 | 1 | 1 |
Spin 3 | 74 |
| L | H | L | H | L |
| L | 0 | 1 | 0 | 1 | 0 | 0 | 1 | 1 |
Table 42
F232120 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 69 |