NOTE: The following programming instructions include information for two versions of HIMs (Human Interface Modules or parameter units). Refer to the nameplate information on the back of HIM to determine which programming information to use.
Displaying Metering Information
1.Install the HIM on the
2.Turn on machine power.
3.After three to five seconds of initialization, display will show the status display. If drive is in a faulted condition, fault will appear in display; otherwise, drive will read current status. Refer to examples below.
Faulted Drive |
| Normal Condition |
|
|
|
Fault Description |
| Status of Drive |
Fault Number |
| Frequency Commanded |
|
| |
|
|
|
6.Press the Enter key to choose Group Level. Display will read:
Choose Group
Metering
For earlier HIM versions, press the Enter key to choose Main File. Display will read:
Metering
Main File
7.Use the Up and Down arrow keys to select “Metering” if not displayed immediately.
8.Press the Enter key to choose Parameter Level. Display now shows parameters under the “Metering” Group.
Examples of Faults
Serial Fault
F 10
Max Retries Fault F 33
Example of Normal
Condition
Stopped
+0.00 Hz
Output Current
|
| 0.00 Amps |
| |
|
|
|
|
|
9. | Use the Up and Down arrow keys | to | ||
| select desired parameter display. |
| ||
10. | From this point, press the Escape key | ESC to | ||
| move display up one Level (i.e., press the Escape | |||
| key three times to return to Operator Level). |
4. Press any key to enter Mode Level,
ESC SEL
. Display will read:
Choose Mode
Display
5.Use the Up and Down arrow keys to select “Display” if not displayed immediately.