PowerFlex 40 and 400 Drive Control Logic

PowerFlex 40 Drive Control Logic Chart

Cabinet Freestanding

WE-6 control

H – Signal Voltage High (approximately 24V DC)

 

 

 

 

 

 

 

 

0 = No signal received

 

 

L – Signal Voltage Low (less than 1V DC)

 

 

 

 

 

 

 

 

 

1 = Signal received

 

 

 

 

Digital

Digital

Digital

Stop

Rev

Fwd

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In 3

In 2

In 1

 

Digital Input

Control Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status – Parameter

Status – Parameter

DC Volt Meter Red Probe Terminal Location

07

06

05

01

03

02

 

 

d014

 

 

d013

 

DC Volt Meter Black Probe Terminal Location

04

04

04

04

04

04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

Terminal

Terminal

Terminal

Terminal

Terminal

Terminal

*DigitalIn 4

 

InDigital3 (SW3)

InDigital2 (SW2)

InDigital1 (SW1)

TransDB On

Stop

(STR)Rev

(STF)Fwd

Action

Preset

#07

#06

#05

#01

#03

#02

 

 

 

 

 

 

 

 

 

 

Parameter #

(SW3)

(SW2)

(SW1)

(Stop)

(STR)

(STF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Idle

N/A

H

H

H

L/H

H

H

0

 

0

0

0

0

0/1

0

0

1/2 Wash Speed Forward

74

L

H

H

L

H

L

*1

 

1

0

0

0

1

0

1

1/2 Wash Speed Reverse

74

L

H

H

L

L

H

0

 

1

0

0

0

1

1

0

Wash Speed Forward

72

H

L

H

L

H

L

*1

 

0

1

0

0

1

0

1

Wash Speed Reverse

72

H

L

H

L

L

H

0

 

0

1

0

0

1

1

0

Distribution Speed

71

H

H

L

L

H

L

*1

 

0

0

1

0

1

0

1

Medium Extract

76

L

L

H

L

H

L

*1

 

1

1

0

0

1

0

1

High 1 Extract

75

L

H

L

L

H

L

*1

 

1

0

1

0

1

0

1

High 2 Extract

73

H

L

L

L

H

L

*1

 

0

1

1

0

1

0

1

High 3 Extract

77

L

L

L

L

H

L

*1

 

1

1

1

0

1

0

1

*If digital in 4 is wired to the Forward Input terminal #02, this input will be a “1” whenever the drive receives a forward command. Disregard otherwise.

Table 12

PowerFlex 400 Drive Control Logic Chart

Cabinet Freestanding (250 Model Only)

WE-6 control

H – Signal Voltage High (greater than 10V DC)

 

 

 

 

 

 

 

 

0 = No signal received

 

 

L – Signal Voltage Low (less than 1V DC)

 

 

 

 

 

 

 

 

1 = Signal received

 

 

 

 

Digital

Digital

Digital

Fwd

Stop

Rev

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In 3

In 2

In 1

 

 

 

 

 

 

 

 

 

 

 

 

 

Control Input Status – Parameter d302

DC Volt Meter Red Probe Terminal Location

07

06

05

02

01

03

 

 

 

 

 

 

 

 

DC Volt Meter Black Probe Terminal Location

04

04

04

04

04

04

 

 

 

 

 

 

 

 

 

Frequency

Terminal

Terminal

Terminal

Terminal

Terminal

Terminal

Not Used

*Digital In 4

Digital In 3 (SW3)

Digital In 2 (SW2)

Digital In 1 (SW1)

Stop

Rev (STR)

Fwd (STF)

Action

Preset

#07

#06

#05

#02

#01

#03

 

Parameter #

(SW3)

(SW2)

(SW1)

(STF)

(Stop)

(STR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Idle

N/A

H

H

H

H

L or H

H

0

0

0

0

0

0/1

0

0

1/2 Wash Speed Forward

355

L

H

H

L

L

H

0

*1

1

0

0

1

0

1

1/2 Wash Speed Reverse

355

L

H

H

H

L

L

0

0

1

0

0

1

1

0

Wash Speed Forward

145

H

L

H

L

L

H

0

*1

0

1

0

1

0

1

Wash Speed Reverse

145

H

L

H

H

L

L

0

0

0

1

0

1

1

0

Distribution Speed

144

H

H

L

L

L

H

0

*1

0

0

1

1

0

1

Medium Extract

357

L

L

H

L

L

H

0

*1

1

1

0

1

0

1

High 1 Extract

356

L

H

L

L

L

H

0

*1

1

0

1

1

0

1

High 2 Extract

146

H

L

L

L

L

H

0

*1

0

1

1

1

0

1

High 3 Extract

358

L

L

L

L

L

H

0

*1

1

1

1

1

0

1

*If digital in 4 is wired to the Forward Input terminal #02, this input will be a “1” whenever the drive receives a forward command. Disregard otherwise.

Table 13

18