Fault Display and Troubleshooting Information
This section provides information to guide users in understanding drive fault conditions and general troubleshooting procedures for
Each drive is equipped with a fault indicator light which illuminates when a fault condition exists.
Fault Code Identification
When the
Once the HIM is installed, the current fault condition is displayed as shown below with the corresponding fault code. Cross reference the number in Table 45 for fault identification and possible corrective action.
Serial Fault
F 10
In addition,
.
Fault Buffer 0
48
The fault parameters are identified as follows:
“Last Fault” | Parameter #4 | Most Recent |
“Fault Buffer 0” | Parameter #86 | Most Recent |
|
| (same as |
|
| Parameter #4) |
“Fault Buffer 1” | Parameter #87 | — |
“Fault Buffer 2” | Parameter #88 | — |
“Fault Buffer 3” | Parameter #89 | Least Recent |
Clearing Faults
When a fault occurs, the cause must be corrected before the fault can be cleared. Resetting a fault will not correct the cause of the fault condition. After corrective action has been taken, simply cycling power to the drive will clear the fault.
Fault Indicator Light
Blank Panel
U076ME3A
Figure 46
80 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232120 |