Viewing a Display Group
(Parameters #1 – 16 for Series A & B or Parameters #1 – 19 for Series C)
1.Install PKM on
2.Turn on machine power.
3.Select the desired parameter by pressing the Up
and Down arrow keys . The parameter value is shown in the last four digits of the display.
0 | 1 | 0. | 0 |
CAUTION
Users are prohibited from changing parameter values unless specifically instructed by the
W673
Viewing a Program Group
(Parameters #30 – 80 for Series A & B or Parameters #30 – 86 for Series C)
1.Install PKM on
2.Turn on machine power.
3.The PKM begins in Display. Press the ESC key
ESC to enter the Program Group.
NOTE: Confirmation of the mode is presented by a decimal point after the second parameter digit.
4.Parameter #30 should be displayed if entering the program group for the first time.
5.From this point, parameters #30 – 80 can be viewed by pressing the Up and Down arrow keys
.
3 | 0. | 5. | 0 |
6.To exit the Program Group, press the ESC key ESC .
Display Mode Parameter Set
1Output Frequency
2Output Voltage
3Output Current
4Output Power
5Bus Voltage
6Frequency Command
7Last Fault
8Heatsink Temperature
9Controller Status
10Controller Type
11Control Version
12Input Status
13Power Factor Angle
14Memory Probe Address
15Preset Status
16Balance Angle
|
|
*17 | Fault Buffer 0 |
*18 | Fault Buffer 1 |
*19 | Fault Buffer 2 |
Table 33
F232120 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 53 |