Viewing a Display Group

(Parameters #1 – 16 for Series A & B or Parameters #1 – 19 for Series C)

1.Install PKM on A-B 160 drive. Refer to “Installation/Removal”.

2.Turn on machine power.

3.Select the desired parameter by pressing the Up

and Down arrow keys . The parameter value is shown in the last four digits of the display.

0

1

0.

0

CAUTION

Users are prohibited from changing parameter values unless specifically instructed by the washer-extractor manufacturer. Modification to parameter values may present potential harmful operating conditions for both hardware and personnel.

W673

Viewing a Program Group

(Parameters #30 – 80 for Series A & B or Parameters #30 – 86 for Series C)

1.Install PKM on A-B 160 drive. Refer to “Installation/Removal.”

2.Turn on machine power.

3.The PKM begins in Display. Press the ESC key

ESC to enter the Program Group.

NOTE: Confirmation of the mode is presented by a decimal point after the second parameter digit.

4.Parameter #30 should be displayed if entering the program group for the first time.

5.From this point, parameters #30 80 can be viewed by pressing the Up and Down arrow keys

.

3

0.

5.

0

6.To exit the Program Group, press the ESC key ESC .

Allen-Bradley 160-Series AC Drives

Display Mode Parameter Set

1Output Frequency

2Output Voltage

3Output Current

4Output Power

5Bus Voltage

6Frequency Command

7Last Fault

8Heatsink Temperature

9Controller Status

10Controller Type

11Control Version

12Input Status

13Power Factor Angle

14Memory Probe Address

15Preset Status

16Balance Angle

 

 

*17

Fault Buffer 0

*18

Fault Buffer 1

*19

Fault Buffer 2

Table 33