| PowerFlex 40 and 400 Drive Control Logic | ||
| Table 16 (continued) |
| ||
|
|
|
| |
PowerFlex 40 | PowerFlex 400 Parameter Group | Parameter |
| |
Parameter | Function | |||
Group and | and Number | Description | ||
| ||||
Number |
|
|
| |
|
|
|
| |
d016 | d320 | Control | Displays the AC drive's firmware | |
|
| Firmware | version. For PowerFlex 40 drives, this | |
|
| Version | will be 70.xx, 80.xx or 90.xx. For | |
|
|
| PowerFlex 400 drives, this will be 14.01. | |
|
|
|
| |
d017 | d321 | Drive Type | Displays the numeric code of the drive's | |
|
|
| rating (e.g., 4508 = 5hp 200V drive) | |
|
|
|
| |
d018 | b012 | Elapsed Run | Displays the accumulated time the drive | |
|
| Time | has output power. The display is in 10- | |
|
|
| hour increments (e.g., a display of 1 | |
|
|
| represents a value of 10 hours). | |
|
|
|
| |
d019 | d319 | Testpoint Data | Displays a hexadecimal value of the | |
|
|
| “Testpoint Selection” in parameter | |
|
|
| A102. | |
|
|
|
| |
d020 | d305 | Analog In | Displays the value (in percentage) of the | |
|
| voltage at terminal 13(e.g., | ||
|
|
| 100.0%=10V) | |
|
|
|
| |
d021 | d306 | Analog In | Displays the value (in percentage) of the | |
|
| current at terminal 15 (e.g., 0.0%=4mA; | ||
|
|
| 100.0%=20mA) | |
|
|
|
| |
d022 | b010 | Output Power | Displays the kilowatts present at | |
|
|
| terminals U, V and W (in kW). | |
|
|
|
| |
d023 | d318 | Output Power | Displays the angle in electrical degrees | |
|
| Factor | between the motor voltage and the motor | |
|
|
| current. | |
|
|
|
| |
d024 | b014 | Drive | Displays the present operating | |
|
| Temperature | temperature (in Celsius) of the drive's | |
|
|
| internal power devices. Refer to Fault | |
|
|
| 008 in Table 20. | |
|
|
|
| |
d025 | N/A | Counter Status | Not applicable to Alliance Laundry | |
|
|
| Systems' equipment. Refer to the manual | |
|
|
| supplied with the PowerFlex drive for | |
|
|
| detailed information. | |
|
|
|
| |
d026 | N/A | Timer Status | Not applicable to Alliance Laundry | |
|
|
| Systems' equipment. Refer to the manual | |
|
|
| supplied with the PowerFlex drive for | |
|
|
| detailed information. | |
|
|
|
| |
d028 | N/A | Step Logic | Not applicable to Alliance Laundry | |
|
| Status | Systems' equipment. Refer to the manual | |
|
|
| supplied with the PowerFlex drive for | |
|
|
| detailed information. | |
|
|
|
| |
| Table 16 (continued) |
|
F232120 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 25 |