![](/images/backgrounds/235058/235058-11121x1.png)
PowerFlex 40 and 400 Drive Control Logic
PowerFlex 40 Drive Control Logic Chart
Pocket Hardmount - IPH, IP and CP Models
PS40 control
H – Signal Voltage High (approximately 24V DC) |
|
|
|
| 0 = No signal received | |||
L – Signal Voltage Low (less than 1V DC) |
|
|
|
| 1 = Signal received |
| ||
| Stop | Rev | Fwd |
|
|
|
|
|
|
| Control Input Status – | ||||||
DC Volt Meter Red Probe Terminal Location | 01 | 03 | 02 |
| ||||
|
| Parameter d013 |
| |||||
DC Volt Meter Black Probe Terminal Location | 04 | 04 | 04 |
|
|
| ||
|
|
|
|
| ||||
Action | Terminal | Terminal | Terminal |
| TransDB On | Stop | Rev | Fwd |
|
|
|
|
| ||||
#01 | #03 | #02 |
|
|
|
|
| |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| |
Idle | L | H | H | 0 | 1 | 0 | 0 | |
Wash Speed Forward | L | H | L | 0 | 1 | 0 | 1 | |
Wash Speed Reverse | L | L | H | 0 | 1 | 1 | 0 | |
Distribution Speed | L | H | L | 0 | 1 | 0 | 1 | |
Low Spin Speed | L | H | L | 0 | 1 | 0 | 1 | |
Medium Spin Speed | L | H | L | 0 | 1 | 0 | 1 | |
High Spin Speed | L | H | L | 0 | 1 | 0 | 1 | |
SmartSpin | L | L | L | 0 | 1 | 1 | 1 |
NOTE: IPH models use analog signals to control speed - refer to parameter d002 (command freq.) and d020 (analog input %) to verify speed input signal.
Table 14
F232120 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 19 |