PowerFlex 40 and 400 Drive Control Logic

PowerFlex Drive Parameters

PowerFlex 40

PowerFlex 400 Parameter Group

Parameter

 

Parameter

Function

Group and

and Number

Description

 

Number

 

 

 

 

 

 

 

d001

b001

Output

Displays instantaneous output frequency

 

 

Frequency

(in Hz).

 

 

 

 

d002

b002

Command

Displays command output frequency (in

 

 

Frequency

Hz).

 

 

 

 

d003

b003

Output Current

Displays output current (in Amps).

 

 

 

 

d004

b004

Output Voltage

Displays output voltage (in VAC).

 

 

 

 

d005

b005

DC Bus Voltage

Displays DC Bus capacitor voltage (in

 

 

 

VDC).

 

 

 

 

d006

b006

Drive Status

Read from left to right, the four bits

 

 

 

indicate the drive's condition

 

 

 

(decelerating, accelerating, forward and

 

 

 

running). “0” = false and “1” = true

 

 

 

 

d007

d307

Fault 1 Code

Memory location for the most recent

 

 

 

fault. Refer to Table 20 for a list of most

 

 

 

fault codes. Repetitive faults are stored

 

 

 

only once.

 

 

 

 

d008

d308

Fault 2 Code

Memory location for the 2nd most recent

 

 

 

fault. Refer to Table 20 for a list of most

 

 

 

fault codes. Repetitive faults are stored

 

 

 

only once.

 

 

 

 

d009

d309

Fault 3 Code

Memory location for the 3rd most recent

 

 

 

fault. Refer to Table 20 for a list of most

 

 

 

fault codes. Repetitive faults are stored

 

 

 

only once.

 

 

 

 

d010

b008

Process Display

Not applicable to Alliance Laundry

 

 

 

Systems’ equipment. Refer to the

 

 

 

manual supplied with the PowerFlex

 

 

 

drive for detailed information.

 

 

 

 

d012

d301

Control Source

Read from left to right, the digits

 

 

 

indicate the active source of the Speed

 

 

 

Reference (P038) and Start Source

 

 

 

(P036) command.

 

 

 

 

d013

d302

Control Input

Refer to Table 8 through Table 14 for

 

 

Status

Control Status Input diagnostics.

 

 

 

 

d014

d302

Digital Input

Refer to Table 8 through Table 14 for

 

 

Status

Digital Input Status diagnostics.

 

 

 

 

d015

d303

Communication

Not applicable to Alliance Laundry

 

 

Status

Systems' equipment. Refer to the manual

 

 

 

supplied with the PowerFlex drive for

 

 

 

detailed information.

 

 

 

 

 

Table 16 (continued)

 

24

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232120