Selecting a Parameter

There are two methods for selecting and viewing Display and Program Group parameters: scrolling through the parameters or entering the parameter number with the numeric keypad.

Scroll Parameter List

1.Connect CopyCat Keypad to Drive. Refer to “Installation/Removal” in this section.

2.Turn on machine power.

3.For Display Group parameters (#1 – 19), press the Escape key ESC until the Program LED and

Load LED are both off; for Program Group parameters (#30 – 86), press the Escape key until the Program LED lights.

4. Press the Up or Down arrow key to scroll to the next or previous parameter. Press and hold the Up or Down arrow key to increase scrolling speed.

Enter Parameter Number

1.Connect CopyCat Keypad to Drive. Refer to “Installation/Removal”.

2.Turn on machine power.

3.For Display Group parameters (#1 – 19), press the Escape key ESC until the Program LED and

Load LED are both off; for Program Group parameters (#30 – 86), press the Escape key until the Program LED lights.

Allen-Bradley 160-Series AC Drives

4.Enter the desired two-digit parameter number using the numeric keys.

The display shows the parameter number entered. For example: >17.

Output Current

P-03: 0.00 >17

To correct an entry, press the Delete key DEL .

5.Press the Enter key , and the newly selected parameter name, number and value are displayed.

Fault Buffer 0

P-17: Under Volt

If the parameter number entered does not exist, an error message is displayed.

ERROR, No

Parameter P-33

6.Press the Enter key or the Escape key ESC to return to the previous parameter.

NOTE: Ensure the parameter to be displayed is in

the group that is currently being displayed: Display Group (#1 – 19) or Program Group (#30 – 86). Refer to Step 3.