160 Series Drive Control Logic Chart
Cabinet Hardmount
A Control, B control, V control and EDC/Netmaster control
H – Control Voltage High (greater than 10V DC) |
|
|
|
|
|
|
|
|
| 0 = No signal received |
|
| |||||||
L – Control Voltage Low (less than 1V DC) |
|
|
|
|
|
|
|
|
|
| 1 = Signal received |
|
| ||||||
|
| SW3 | SW2 | SW1 | STF | Stop | STR |
|
|
|
|
|
|
|
|
|
|
| |
|
| Preset Status – | Input Status – | ||||||||||||||||
DC Volt Meter Red Probe Terminal Location | 4 | 2 | 1 | 6 | 8 | 5 | |||||||||||||
| Parameter 15 |
| Parameter 12 | ||||||||||||||||
DC Volt Meter Black Probe Terminal Location | 3 | 3 | 3 | 3 | 3 | 3 |
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||
| Frequency | Terminal | Terminal | Terminal | Terminal | Terminal | Terminal | UsedNot |
| SW3 |
| SW2 | SW1 | UsedNot |
| STF | Stop | STR | |
Action | Preset | #4 | #2 | #1 | #6 | #8 | #5 |
|
|
|
|
|
|
|
|
|
|
| |
| Parameter # | (SW3) | (SW2) | (SW1) | (STF) | (Stop) | (STR) |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Idle | N/A | H | H | H | H | L/H | H | 0 |
| 0 |
| 0 | 0 | 0 |
| 0 | 0/1 | 0 | |
1/2 Wash Speed Forward | 62 | H | H | L | L | L | H | 0 |
| 0 |
| 0 | 1 | 0 |
| 1 | 1 | 0 | |
1/2 Wash Speed Reverse | 62 | H | H | L | H | L | L | 0 |
| 0 |
| 0 | 1 | 0 |
| 0 | 1 | 1 | |
Wash Speed Forward | 63 | H | L | H | L | L | H | 0 |
| 0 |
| 1 | 0 | 0 |
| 1 | 1 | 0 | |
Wash Speed Reverse | 63 | H | L | H | H | L | L | 0 |
| 0 |
| 1 | 0 | 0 |
| 0 | 1 | 1 | |
Distribution Speed | 65 | L | H | H | L | L | H | 0 |
| 1 |
| 0 | 0 | 0 |
| 1 | 1 | 0 | |
Spin 1 | 64 | H | L | L | L | L | H | 0 |
| 0 |
| 1 | 1 | 0 |
| 1 | 1 | 0 | |
Spin 2 | 67 | L | L | H | L | L | H | 0 |
| 1 |
| 1 | 0 | 0 |
| 1 | 1 | 0 | |
Spin 3 | 66 | L | H | L | L | L | H | 0 |
| 1 |
| 0 | 1 | 0 |
| 1 | 1 | 0 |
Table 28
44 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232120 |