PowerFlex 40 and 400 Drive Control Logic

2

1

RUN

VOLTS

FWD

AMPS

REV

HERTZ

PROGRAM

FAULT

3

4

5

 

8

6

 

 

 

 

7

 

 

POWERFLEX KEYPAD BUTTONS

 

 

PHM640

 

 

 

Number

Name

Description

1

Escape

Back one step in programming menu.

 

Cancel a change to a parameter value and exit Program Mode.

 

 

2

Select

Advance one step in programming menu.

 

Select a digit when viewing parameter value.

 

 

3

Up Arrow

Scroll through groups and parameters.

Down Arrow

Increase/decrease the value of a flashing digit.

 

4

Enter

Advance one step in programming menu.

 

Save a change to a parameter value.

 

 

5

Stop

Used to stop the drive or clear a fault. This key is always active.

 

Controlled by parameter P037 (Stop Mode).

 

 

6

Reverse

Used to reverse direction of the drive. Default is active.

 

Controlled by parameters P036 (Start Source) and A095 (Reverse Disable).

 

 

7

Start

Used to start the drive. Default is active.

 

Controlled by parameters P036 (Start Source).

 

 

8

Potentiometer

Used to control speed of drive. Default is active.

 

Controlled by parameter P038 (Speed Reference).

 

 

Figure 19

30

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232120