Allen-Bradley 1305-Series AC Drives

Control Logic Chart

Pocket Hardmount

V Control

H – Control Voltage High (approximately 5V DC)

 

 

 

 

 

 

 

 

 

 

0 = No Signal Received

 

 

L – Control Voltage Low (less than 1V DC)

 

 

 

 

 

 

 

 

 

 

1 = Signal Received

 

 

 

 

 

 

SW3

SW2

SW1

Rev

Stop

Fwd

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC Volt Meter Red Probe Terminal Location

18

 

17

16

13

8

6

 

Input Status - Parameter #55

 

DC Volt Meter Black Probe Terminal Location

7

 

7

7

7

7

7

 

 

 

 

 

 

 

 

 

 

Frequency

Terminal

 

Terminal

Terminal

Terminal

Terminal

Terminal

UsedNot

SW3

SW2

SW1

UsedNot

(STR)Rev

Stop

(STF)Fwd

Action

 

Preset

#18

 

#17

#16

#13

#8

#6

 

 

 

 

 

 

 

 

 

 

Parameter

(SW3)

 

(SW2)

(SW1)

(STR)

(Stop)

(STF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Idle

 

 

N/A

H

 

H

H

H

L/H

H

0

0

0

0

0

0

0/1

0

1/2 Wash Speed Forward

 

27

H

 

H

L

H

L

L

0

0

0

1

0

0

1

1

1/2 Wash Speed Reverse

 

27

H

 

H

L

L

L

H

0

0

0

1

0

1

1

0

Wash Speed Forward

 

28

H

 

L

H

H

L

L

0

0

1

0

0

1

1

0

Wash Speed Reverse

 

28

H

 

L

H

L

L

H

0

1

0

0

0

0

1

1

Distribution Speed

 

73

L

 

H

H

H

L

L

0

1

0

0

0

0

1

1

Spin 1

 

29

L

 

L

H

H

L

L

0

1

1

1

0

0

1

1

Spin 2

 

75

L

 

L

H

H

L

L

0

1

1

0

0

0

1

1

Spin 3

 

74

L

 

H

L

H

L

L

0

1

0

1

0

0

1

1

Pocket Hardmount

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WE-6 Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H – Control Voltage High (approximately 5V DC)

 

 

 

 

 

 

 

 

 

 

0 = No Signal Received

 

 

L – Control Voltage Low (less than 1V DC)

 

 

 

 

 

 

 

 

 

 

1 = Signal Received

 

 

 

 

 

 

SW3

SW2

SW1

Rev

Stop

Fwd

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC Volt Meter Red Probe Terminal Location

18

 

17

16

13

8

6

 

Input Status - Parameter #55

 

DC Volt Meter Black Probe Terminal Location

7

 

7

7

7

7

7

 

 

 

 

 

 

 

 

 

 

Frequency

Terminal

 

Terminal

Terminal

Terminal

Terminal

Terminal

UsedNot

SW3

SW2

SW1

UsedNot

(STR)Rev

Stop

(STF)Fwd

Action

 

Preset

#18

 

#17

#16

#13

#8

#6

 

 

 

 

 

 

 

 

 

 

Parameter

(SW3)

 

(SW2)

(SW1)

(STR)

(Stop)

(STF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Idle

 

 

N/A

H

 

H

H

H

L/H

H

0

0

0

0

0

0

0/1

0

Half-Wash Speed Forward

 

73

L

 

H

H

H

L

L

0

1

0

0

0

0

1

1

Half-Wash Speed Reverse

 

73

L

 

H

H

L

L

L

0

1

0

0

0

1

1

0

Wash Speed Forward

 

28

H

 

L

H

H

L

L

0

0

1

0

0

0

1

1

Wash Speed Reverse

 

28

H

 

L

H

L

L

H

0

0

1

0

0

1

1

0

Distribution Speed

 

27

H

 

H

L

H

L

L

0

0

1

0

0

1

1

0

Medium Extract/Spray Rinse

 

75

L

 

L

H

H

L

L

0

1

1

0

0

0

1

1

High 1 Extract

 

74

H

 

L

L

H

L

L

0

1

0

1

0

0

1

1

High 2 Extract

 

29

H

 

L

L

H

L

L

0

0

1

1

0

0

1

1

High 3 Extract

 

76

L

 

L

L

H

L

L

0

1

1

1

0

0

1

1

 

 

 

 

 

 

 

Table 40

 

 

 

 

 

 

 

 

 

 

Control Terminal (TB2) Torque Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max/Min Wire Size

 

Maximum Torque

 

 

 

 

 

 

 

 

 

 

 

 

 

mm2 AWG

 

 

N-m (lb-in)

 

 

 

 

 

 

 

 

 

 

 

 

 

1.5/0.20

 

 

 

0.90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(14/24)

 

 

 

(8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 41

68

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232120