Control Logic Chart
Pocket Hardmount
V Control
H – Control Voltage High (approximately 5V DC) |
|
|
|
|
|
|
|
|
|
| 0 = No Signal Received |
|
| ||||||
L – Control Voltage Low (less than 1V DC) |
|
|
|
|
|
|
|
|
|
| 1 = Signal Received |
|
| ||||||
|
|
|
| SW3 | SW2 | SW1 | Rev | Stop | Fwd |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
DC Volt Meter Red Probe Terminal Location | 18 |
| 17 | 16 | 13 | 8 | 6 |
| Input Status - Parameter #55 |
| |||||||||
DC Volt Meter Black Probe Terminal Location | 7 |
| 7 | 7 | 7 | 7 | 7 |
|
|
|
|
|
|
|
| ||||
|
| Frequency | Terminal |
| Terminal | Terminal | Terminal | Terminal | Terminal | UsedNot | SW3 | SW2 | SW1 | UsedNot | (STR)Rev | Stop | (STF)Fwd | ||
Action |
| Preset | #18 |
| #17 | #16 | #13 | #8 | #6 |
|
|
|
|
|
|
|
| ||
|
| Parameter | (SW3) |
| (SW2) | (SW1) | (STR) | (Stop) | (STF) |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Idle |
|
| N/A | H |
| H | H | H | L/H | H | 0 | 0 | 0 | 0 | 0 | 0 | 0/1 | 0 | |
1/2 Wash Speed Forward |
| 27 | H |
| H | L | H | L | L | 0 | 0 | 0 | 1 | 0 | 0 | 1 | 1 | ||
1/2 Wash Speed Reverse |
| 27 | H |
| H | L | L | L | H | 0 | 0 | 0 | 1 | 0 | 1 | 1 | 0 | ||
Wash Speed Forward |
| 28 | H |
| L | H | H | L | L | 0 | 0 | 1 | 0 | 0 | 1 | 1 | 0 | ||
Wash Speed Reverse |
| 28 | H |
| L | H | L | L | H | 0 | 1 | 0 | 0 | 0 | 0 | 1 | 1 | ||
Distribution Speed |
| 73 | L |
| H | H | H | L | L | 0 | 1 | 0 | 0 | 0 | 0 | 1 | 1 | ||
Spin 1 |
| 29 | L |
| L | H | H | L | L | 0 | 1 | 1 | 1 | 0 | 0 | 1 | 1 | ||
Spin 2 |
| 75 | L |
| L | H | H | L | L | 0 | 1 | 1 | 0 | 0 | 0 | 1 | 1 | ||
Spin 3 |
| 74 | L |
| H | L | H | L | L | 0 | 1 | 0 | 1 | 0 | 0 | 1 | 1 | ||
Pocket Hardmount |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
H – Control Voltage High (approximately 5V DC) |
|
|
|
|
|
|
|
|
|
| 0 = No Signal Received |
|
| ||||||
L – Control Voltage Low (less than 1V DC) |
|
|
|
|
|
|
|
|
|
| 1 = Signal Received |
|
| ||||||
|
|
|
| SW3 | SW2 | SW1 | Rev | Stop | Fwd |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
DC Volt Meter Red Probe Terminal Location | 18 |
| 17 | 16 | 13 | 8 | 6 |
| Input Status - Parameter #55 |
| |||||||||
DC Volt Meter Black Probe Terminal Location | 7 |
| 7 | 7 | 7 | 7 | 7 |
|
|
|
|
|
|
|
| ||||
|
| Frequency | Terminal |
| Terminal | Terminal | Terminal | Terminal | Terminal | UsedNot | SW3 | SW2 | SW1 | UsedNot | (STR)Rev | Stop | (STF)Fwd | ||
Action |
| Preset | #18 |
| #17 | #16 | #13 | #8 | #6 |
|
|
|
|
|
|
|
| ||
|
| Parameter | (SW3) |
| (SW2) | (SW1) | (STR) | (Stop) | (STF) |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Idle |
|
| N/A | H |
| H | H | H | L/H | H | 0 | 0 | 0 | 0 | 0 | 0 | 0/1 | 0 | |
| 73 | L |
| H | H | H | L | L | 0 | 1 | 0 | 0 | 0 | 0 | 1 | 1 | |||
| 73 | L |
| H | H | L | L | L | 0 | 1 | 0 | 0 | 0 | 1 | 1 | 0 | |||
Wash Speed Forward |
| 28 | H |
| L | H | H | L | L | 0 | 0 | 1 | 0 | 0 | 0 | 1 | 1 | ||
Wash Speed Reverse |
| 28 | H |
| L | H | L | L | H | 0 | 0 | 1 | 0 | 0 | 1 | 1 | 0 | ||
Distribution Speed |
| 27 | H |
| H | L | H | L | L | 0 | 0 | 1 | 0 | 0 | 1 | 1 | 0 | ||
Medium Extract/Spray Rinse |
| 75 | L |
| L | H | H | L | L | 0 | 1 | 1 | 0 | 0 | 0 | 1 | 1 | ||
High 1 Extract |
| 74 | H |
| L | L | H | L | L | 0 | 1 | 0 | 1 | 0 | 0 | 1 | 1 | ||
High 2 Extract |
| 29 | H |
| L | L | H | L | L | 0 | 0 | 1 | 1 | 0 | 0 | 1 | 1 | ||
High 3 Extract |
| 76 | L |
| L | L | H | L | L | 0 | 1 | 1 | 1 | 0 | 0 | 1 | 1 | ||
|
|
|
|
|
|
| Table 40 |
|
|
|
|
|
|
|
|
|
| ||
Control Terminal (TB2) Torque Specifications |
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Max/Min Wire Size |
| Maximum Torque |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
mm2 AWG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
1.5/0.20 |
|
|
| 0.90 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
(14/24) |
|
|
| (8) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Table 41
68 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232120 |