Viewing and Editing Parameters

The last user-selected Display Group parameter is saved when power is removed and is displayed by default when power is reapplied.

PowerFlex 40 and 400 Drive Control Logic

The following is an example of basic integral keypad and display functions. This example provides basic navigation instructions and illustrates how to program the first Program Group parameter.

Step

Description

Key(s)

Example

Displays

 

 

 

 

When power is applied, the last user-selected Display Group

 

VOLTS

 

parameter number is briefly displayed with flashing characters. The

 

AMPS

1

 

 

HERTZ

display then defaults to that parameter’s current value. (Example

PROGRAM

FAULT

 

shows the value of d001 [Output Freq.] with the drive stopped.)

 

 

2

Press Esc or Sel until the Group Menu letter begins to flash.

 

VOLTS

 

or

AMPS

 

 

HERTZ

 

 

PROGRAM

FAULT

3

Press the Up Arrow or Down Arrow to scroll through the group menu

 

 

(d, P and A).

or

 

 

 

 

4

Press Enter or Sel to enter a group. The right digit of the last viewed

or

VOLTS

parameter in that group will flash.

AMPS

 

 

 

HERTZ

 

 

PROGRAM

FAULT

5

Press the Up Arrow or Down Arrow to scroll through the parameters

 

 

that are in the group.

or

 

 

 

 

6

Press Enter or Sel to view the value of a parameter. If you do not want

or

VOLTS

to edit the value, press Esc to return to the parameter number.

AMPS

 

 

 

HERTZ

 

 

PROGRAM

FAULT

 

Press Enter or Sel to enter program mode to edit the parameter value.

or

VOLTS

7

The right digit will flash and the Program LED will illuminate if the

FAULT

PROGRAM

 

 

 

AMPS

 

 

 

HERTZ

 

parameter can be edited.

 

 

 

Press the Up Arrow or Down Arrow to change the parameter value. If

or

 

8

desired, press Sel to move from digit to digit or bit to bit. The digit or

 

 

 

 

bit that you can change will flash.

 

 

Press Esc to cancel a change. The digit will stop flashing, the previous value is restored and the Program LED will turn off.

9OR

 

Press Enter to save a change. The digit will stop flashing and the

 

VOLTS

 

 

 

AMPS

 

Program LED will turn off.

 

HERTZ

 

PROGRAM

FAULT

 

Press Esc to return to the parameter list. Continue to press Esc to back

 

VOLTS

 

out of the programming menu.

 

AMPS

10

 

 

HERTZ

If pressing Esc does not change the display, then d001 (Output

PROGRAM

FAULT

 

 

 

 

Frequency) is displayed. Press Enter or Sel to enter the group menu.

 

 

 

Table 19

 

 

F232120

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

31