Chapter 3

Hardware

Pin #

Signal

Input/

Description

 

 

 

Output

 

20

(A20)

GND

 

Digital Ground

21

(A21)

AD29

T/S

PCI Address and Data Bus Line 29 – Refer to Pin-3 for more

 

 

 

 

information.

22

(A22)

+5V

 

+5 volt power supply ±5%

23

(A23)

REQ0*

T/S

Bus Request 0 – This signal line is one of three signal lines. These

 

 

 

 

signals indicate the device desires use of the bus to the arbitrator.

24

(A24)

GND

 

Digital Ground

25

(A25)

GNT1*

T/S

Grant 1 – This signal line is one of three signal lines. These signal

 

 

 

 

lines indicate access has been granted to the requesting device

 

 

 

 

(PCI Masters).

26

(A26)

+5V

 

+5 volt power supply ±5%

27

(A27)

CLK2

In

PCI clock 2 – This signal line is one of four signal lines. These

 

 

 

 

clock signals provide the timing outputs for four external PCI

 

 

 

 

devices and the timing for all transactions on the PCI bus

28

(A28)

GND

 

Digital Ground

29

(A29)

+12V

 

+12 volt power supply ±5%

30

(A30)

NC

 

Not connected - Reserved

 

 

 

 

 

31

(B1)

NC

 

Not connected - Reserved

 

 

 

 

 

32

(B2)

AD02

T/S

PCI Address and Data Bus Line 2 – Refer to Pin-3 for more

 

 

 

 

information.

33

(B3)

GND

 

Digital Ground

34

(B4)

AD07

T/S

PCI Address and Data Bus Line 7 – Refer to Pin-3 for more

 

 

 

 

information.

35

(B5)

AD09

T/S

PCI Address and Data Bus Line 9 – Refer to Pin-3 for more

 

 

 

 

information.

36

(B6)

VI/O

 

+5 volt power supply ±5%

37

(B7)

AD13

T/S

PCI Address and Data Bus Lines 13 – Refer to Pin-3 for more

 

 

 

 

information.

38

(B8)

C/BE1*

T/S

PCI Bus Command/Byte Enable 1 – Refer to Pin-4 for more

 

 

 

 

information.

39

(B9)

GND

 

Digital Ground

40

(B10)

PERR*

 

Parity Error – This signal is for reporting data parity errors.

 

 

 

 

 

41

(B11)

+3.3V

 

+3.3 volt power supply ±5%

42

(B12)

TRDY*

S/T/S

Target Ready – This signal indicates the selected device’s ability

 

 

 

 

to complete the current cycle of transaction. Both IRDY* and

 

 

 

 

TRDY* must be asserted to terminate a data cycle

43

(B13)

GND

 

Digital Ground

44

(B14)

AD16

T/S

PCI Address and Data Bus Line 16 – Refer to Pin-3 for more

 

 

 

 

information.

45

(B15)

+3.3V

 

+3.3 volt power supply ±5%

46

(B16)

AD20

T/S

PCI Address and Data Bus Lines 20 – Refer to Pin-3 for more

 

 

 

 

information.

24

Reference Manual

ReadyBoard 700

Page 30
Image 30
Ampro Corporation 700 manual REQ0, GNT1, CLK2, Perr, Trdy