The above option allows unrestricetd correction of the finder image.

Eyepiece

The diopter compensation on the eyepiece is fitted with a scale of 1 to 12. At position 6 middle focus is set.

Unscrewing the Eyepiece

Loosen the knurled ring .

Pull off the eyepiece.

Screwing on the Eyepiece

Attach the eyepiece to the finder.

Ensure that the pin locks into a groove.

Pull the knurled knob tight.

Eyecup

In order to avoid light falling in through the viewfinder the eyecup has a shutter.

Always slide the shutter closed when not using for viewing.

The eyecup can be removed and replaced by the heated eyecup. See chapter 7.

eye cup iris lever knurled retaining ring

Optics