Maintenance

Necessary Special Tools

Depth gauge for PL-mount

or

 

Depth gauge

A 16 SR-18

Depth gauge cylinder

A 16 SR-19

Depth gauge base

A 16 SR-20

Depth gauge plate

A 16 SR-21

Checking the Flange Focal Distance

Adjust the depth gauge with the gauge cylinder on the gauge base to „0“.

Turn the mirror shutter downwards with the inching knob.

Lay the gauge plate on the film gate and check the

flange focal distance with the gauge.

• Standard camera:

52,000 mm -0,010 mm

HS camera:

51,970 mm -0,010 mm

Adjusting the Flange Focal Distance

The flange focal distance can be set with the adjustment shims which sit between the camera housing and the PL- mount.

Check the flange focal distance (see above).

If appropriate remove the compensation adapter.

Unscrew the 6 cylinder head screws.

Remove the PL-mount.

Exchange the adjustment shims, ensuring that they do not get bent, dirtied or twisted in the process.

Replace the PL-mount, ensuring that the marking for the chosen format is in the upper right-hand corner.

Screw in the 6 cylinder head screws.

Pull the 6 cylinder head screws tight before checking the flange focal distance as otherwise a false reading will be attained.

Check the flange focal distance (see above).

90