Adjustment Normal 16/Super 16

Mount the alignment screw SW 1,5 (wrench width 1,5 mm) top right.

Remove stop plate segment and locking knob

after removing the fastening intermediate rings and refasten on the opposite side.

Replace the 6 cylinder head screws and screw tight.

Check viewing screen for focus.

Check flange focal distance.

Changing the Fibre Optic Viewing Screen

For changing the fibre optic viewing screen see chapter 5.

Adjusting the Opening in the Universal Film Gate

For Normal 16 part of the film gate is covered by a rail which is removed when changing to Super 16.

Unscrew the 6 screws on the cover plate

.

Remove the cover plate .

Unscrew the 8 cylinder head screws on the film gate.

Remove the film gate.

Ensure that the adjustment shims are not bent, dirtied or twisted during insertion.

Phillips head screws

rail (std. 16)

50