8. Adjustment Normal 16 /Super 16
16
The centre of the image format is 1 mm different for the Super 16 (12.4 x 7.5 mm) than for Normal 16 (10.3 x
7.5mm). In changing the image format, the lens mount and the viewfinder on the camera must be adjusted 1 mm to centre it. The opening of the Universal film gate is altered merely by addition or removal of a rail. For both formats different fibre optic viewing screens must be used.
Also on the bridge plate, the leightweight support and the video optic the adjustments for Normal 16 or Super 16 must be carried out.
Adjusting on the Camera
Special Tool Kit
Included with camera
Altering the Lens Alignment
•Check Flange focal distance. See Chapter 13 Standard: 52.000 – 0.010 mm
HS: | 51.970 – 0.010 mm |
•Remove the 6 cylinder head screws .
•Turn the lens mount 180° . The desired format (N16 or S16) must be top right.
Ensure that the adjustment shims are not bent, dirtied or twisted during insertion.
lock ring stop
lens locating pin
cylinder head screws
lens
Adjustment Normal 16/Super