INSTALLATION INFORMATION
GENERAL INFORMATION |
|
Wiring | Use #22 AWG minimum for sensor wiring and digital |
| communicator channels. Use #18 AWG minimum for AC power. |
| All wire should be |
Environment | The system is designed to work in an indoor heated environment |
| (40 to 120 degrees F.) Battery life may be significantly reduced if |
| components are in direct sunlight or in an unheated location. |
U.L. Requirements | UL requires that any fire application includes either a Supervised |
| Smoke Detector Transmitter or a Universal Transmitter |
| configured for fire and connected to a |
| smoke detector with relay. Other types of smoke/fire sensors |
| (suck as heat sensors) may be included in the system. |
| The Universal Transmitter sbould be used in its supervised mode |
| unless it is being used as a portable device. |
| If the internal sounder on the Central controller or Wireless |
| Siren/controller is silenced for intrusion alarms (DIP switch |
| option) there should be an auxiliary sounding device in the system. |
| The Wheelock |
| siren or horn interface. |
| Open loop sensor connections at any transmitter or Central |
| Controller should be less 3 feet in length with no barriers in |
| between, and the sensor shall be provided with a test feature. |
| All sensors should be |