Appendix C
Auxiliary Power for the 8110 Telephone
If you are using an 8110 telephone, it is recommended that you install auxiliary power (9V DC, 100 mA.) to improve the performance of the speakerphone under the following conditions:
| ● When loop length exceeds: | |
If you are using: | ➤ 19,000 feet (22 gauge) | |
Circuit Pack TN742 | ➤ 12,000 feet (24 gauge) | |
| ||
Circuit Pack TN769 | ➤ 7,500 feet (26 gauge) | |
| ||
| or | |
| ● When loop resistance exceeds 300 ohms | |
| or | |
| ● When loop current is less than 26 mA. | |
|
| |
| ● When loop length exceeds: | |
If you are using: | ➤ 12,000 feet (22 gauge) | |
Circuit Pack SN229 | ➤ 8,000 feet (24 gauge) | |
| ||
| ➤ 5,000 feet (26 gauge) | |
| or | |
| ● When loop resistance exceeds 200 ohms | |
| or | |
| ● When loop current is less than 26 mA. | |
|
| |
Any installation | When loop current is less than 26 mA. | |
|
| |
Any installation | When another analog telephone is bridged | |
with the 8110 telephone | ||
| ||
|
|
35