8410 Voice Terminal

Distance Limitations

The following circuit packs can be used with all of the 8400-Series sets.

Circuit Pack

2/4-Wire

Will support these switches

TN2181 - 16-port

2-wire

G3V3, G3V2

TN754b - 8-port

4-wire

All switches except System 85

TN754 - 8-port

4-wire

All switches except System 85

TN413 - 8-port

4-wire

International System 75

SN 270 and

 

 

SN 270B - 4-port

4-wire

System 85 R2V2 - R2V4

In 4-wire operation, the voice terminal must be within 5,000 feet of the PBX using 22-gauge or 24-gauge wire, and within 4,000 feet of the PBX using 26-gauge wire.

In 2-wire operation, the voice terminal must be within 5,500 feet of the PBX using 22-gauge wire, within 3,500 feet of the PBX using 24-gauge wire, and within 2,200 feet of the PBX using 26-gauge wire.

Power Requirements

The 8410 voice terminal receives power from the system and does not require any external power supply. Additional external power IS required when the 8410 voice terminal is equipped with any adjuncts, such as an external speakerphone. In this instance, an MSP-1 Power Supply is recommended. Refer to the Adjunct Power section of this manual for information on the MSP-1 Power Supply.