EXPOSED PORT PROTECTION

TABLE 2-D. IROB Protection

CIRCUIT

TERMINAL

REQUIRED

SEE

PACKS

PROTECTOR*

NOTE

 

SN224

7203,

EP

 

7205,

 

 

 

MET

 

 

SN228B,

2500 Series,

P

1

SN229

2500DMGC,

 

 

 

7100 Series

 

 

TN742,

500 Series,

P

1

TN746B,

2500 Series,

 

 

TN769

7100 Series

 

 

SN270

7400 Series

EP

TN754

7400 Series

(ITW)

2

TN754, V14

7400 Series

EP

3

TN556

T. Term

EP & P

4

*P = Primary, EP = Enhanced Primary

Notes:

1.Primary protection with heat coils for sneak protection are coded with the number 4 as the first numeric. DEFINITY ports require sneak current protection for IROB terminal installations.

2.The TN754, V1 through V13 may be installed with either the DLP and primary protector or the ITW Linx Enhanced Primary protector. These vintages may not be installed with the 4C3S-75 Enhanced Primary protector.

3.The 4C3S-75 Enhanced Protector may only be used on Vintage 14 or newer TN754 Circuit Packs. The ITW Linx Enhanced Protector may be used on all Vin- tages of the TN754 Circuit Pack.

4.The TN556 Circuit Pack requires Enhanced Primary protection at the port and Primary (3- or 4-type) protection at the terminal.

For more information on exposed port protection, refer to:

DEFINITY Communications System Generic 1 and Generic 3 Wiring, 555-204-111

DEFINITY Communications System Generic 2 and System 85 Wiring, 555-104-630

2-23