8101 Telephone

Distance Limitations

The maximum allowable distances of an 8101 telephone from the DEFINITY G1, G2, G3, System 75, or System 85 cabinet are shown in the table below.

 

 

NOMINAL MAXIMUM RANGE

SYSTEM

PORT BOARD

 

IN FEET (METERS)

 

 

 

24 AWG

26 AWG

System 85

SN229

6,500

(1,981)

4,100

(1,246)

 

SN228B

6,500

(1,981)

4,100

(1,246)

DEFINITY G2

SN229

6,500

(1,981)

4,100

(1,246)

 

SN228B

6,500

(1,981)

4,100

(1,246)

 

TN742

15,200

(4,633)

10,000

(3,050)

 

TN746

3,000 (915)

2,000 (610)

DEFINITY G1 & G3

TN742

15,200

(4,633)

10,000

(3,050)

System 75

TN769

15,200

(4,633)

10,000

(3,050)

 

TN746

3,000 (915)

2,000 (610)

Power Requirements

The 8101 voice terminal receives power from the system and does not require any external power supply.

Switch Administration

The 8101 telephone must be administered in the following ways:

If the 8101 telephone is connected to a System 75 or DEFINITY G1 or G3, it must be administered as a 2500 analog telephone.

If the 8101 telephone is connected to a System 85 or DEFINITY G2, it can be admin- istered as an analog line.

3-352

Page 442
Image 442
AT&T System 85 manual System SN229 500 981 100 246 SN228B