8110 and 8110M Telephones

Power Requirements

It is recommended that the 8110 and 8110M telephones have auxiliary power (9V DC, 100 mA) to improve the performance of the speakerphone under the following conditions:

Note: Use with the TN746 circuit pack requires auxiliary power (in the form of a power adapter) at all loop lengths. On System 85 and DEFINITY G2, the line must be administered as Data Restricted to allow for the automatic disconnect feature.

 

When loop length exceeds:

If you are using:

16,000 feet (22 gauge)

Circuit Pack TN742

10,000 feet (24 gauge)

 

Circuit Pack TN769

6,300 feet (26 gauge)

 

 

or

 

When loop resistance exceeds 256 ohms

 

or

 

When loop current is less than 26 mA

 

When loop length exceeds:

If you are using:

11,000 feet (22 gauge)

Circuit Pack SN229

7,000 feet (24 gauge)

 

 

4,400 feet (26 gauge)

 

or

 

When loop resistance exceeds 180 ohms

 

or

 

When loop current is less than 26 mA

Any installation

When loop current is less than 26 mA

Any installation

When another analog telephone is bridged

with the 8110 or 8110M telephone

 

3-374