2500 Series Telephones

Distance Limitations

The maximum allowable distances of a 2500-series telephone from the DEFINITY G1, G2, G3, System 75, or System 85 cabinet are shown in the table below.

 

 

NOMINAL MAXIMUM RANGE

SYSTEM

PORT BOARD

 

IN FEET (METERS)

 

 

 

24 AWG

26 AWG

SYSTEM 85

SN229

3,500

(1,067)

3,500

(1,067)

 

SN228B

15,000

(4,572)

9,000

(2,743)

DEFINITY G2

SN229

3,500

(1,067)

3,500

(1,067)

 

SN228B

15,000

(4,572)

9,000

(2,743)

 

TN742

20,000

(6,100)

13,000

(3,962)

 

TN746

3,100 (945)

2,000 (610)

DEFINITY G1 & G3

TN742

20,000

(6,100)

13,000

(3,962)

SYSTEM 75

TN769

20,000

(6,100)

13,000

(3,962)

 

TN746

3,100 (945)

2,000 (610)

Power Requirements

The 2500-series telephone is powered by the tip and ring leads. It does not require any external power supply.

Power Failure Operation

The 2500-series telephone can be used as an emergency station during power failure transfer conditions.

FCC Registration

The 2500-series telephone is FCC registered.

3-325

Page 415
Image 415
AT&T System 85 manual series telephone is FCC registered