Security and Configuration

Table 2-2. G3PD Advanced Configuration Parameters

PARAMETER

DEFAULT

COMMENTS

 

 

 

Advertised Vendor

AVAYA

Can be AVAYA or LUCENT. If this is a new

Name

 

installation, choose AVAYA.

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

If you are upgrading Avaya CT and your

 

 

 

 

applications have LUCENT hardcoded in

 

 

 

 

Tlink names, select the LUCENT setting.

 

 

 

**NUM SESSIONS

50

Guideline for number of simultaneous sessions

 

 

(active acsOpenStream requests). The minimum is

 

 

5 and the maximum is 5000.

 

 

 

**NUM CALL

200

Guideline for number of simultaneous

MONITORS

 

cstaMonitorCall requests. The minimum is 5 and

 

 

the maximum is 5000.

 

 

 

**NUM DEVICE

200

Guideline for number of simultaneous

MONITORS

 

cstaMonitorDevice requests. The minimum is 5 and

 

 

the maximum is 5000.

 

 

 

**NUM SESSION

20

Guideline for number of simultaneous (not

REQUESTS

 

confirmed) CSTA requests for a single session

 

 

(open stream). The minimum is 5 and the maximum

 

 

is 5000.

 

 

 

**NUM SESSION

40

Guideline for number of active device or call

MONITORS

 

monitors for a single session (open stream). The

 

 

minimum is 5 and the maximum is 5000.

 

 

 

 

 