72AutoView 3100/3200 Switch Installer/User Guide
To use History mode:
1.Press
2.Press one of the following key combinations to perform the indicated action:
•Home: Move to the top of the buffer.
•End: Move to the bottom of the buffer.
•Page Up: Move up one buffer page.
•Page Down: Move down one buffer page.
•Up Arrow: Move up one buffer line.
•Down Arrow: Move down one buffer line.
•
•
•
•
3.When finished, press
AVRIQ-SRL module pinouts
Table B.1 lists the pinouts for the AVRIQ-SRL module.
Table B.1:
Host Signal Name Description | Signal Flow | SRL Signal Name Description | ||
Pin | ||||
|
|
| ||
|
|
|
| |
1 | DCD - Data Carrier Detect | Out of SRL | DTR - Data Terminal Ready | |
|
|
|
| |
2 | RXD - Receive Data | Out of SRL | TXD - Transmit Data | |
|
|
|
| |
3 | TXD - Transmit Data | In to SRL | RXD - Receive Data | |
|
|
|
| |
4 | DTR - Data Terminal Ready | In to SRL | AutoView - Data Set Ready | |
|
|
|
| |
5 | GND - Signal Ground | N/A | GND - Signal Ground | |
|
|
|
| |
6 | AutoView - Data Set Ready | Out of SRL | DTR - Data Terminal Ready | |
|
|
|
| |
7 | RTS - Request to Send | In to SRL | CTS - Clear to Send | |
|
|
|
| |
8 | CTS - Clear to Send | Out of SRL | RTS - Request to Send | |
|
|
|
| |
9 | N/C - Not Connected | N/A | N/C - Not Connected | |
|
|
|
|