26 en | Installing the DINION capture DINION capture 5000 IP
| 1.0 | 2012.01 Installation Manual Bosch Security Systems, Inc.
3.5 Making the Connections
The easiest way to connect the cables is as follows:
1. Bring the building connections through the surface cable
hole so that they hang clear.
2. Connect the Ethernet cable with connector to RJ-45 jack
coming from the DINION capture 5000 IP.
3. Connect the ferrule tipped power wires (red, black;
polarity independent) to the power supply connection if
power is not supplied via PoE+ over the Ethernet cable.
Note: You can connect the imager to a PoE+ and to an 11-
30 VDC / 24 VAC supply simultaneously.
4. In damp environments ensure that the connections are
sealed inside a junction box or a field wiring box with
NEMA 3 or IP55 protection level or better. Make the
connections inside the water tight compartment. After
connections are made ensure that the watertight
compartment is tightly closed and cables and conduits are
properly sealed to prevent ingress of water.
WARNING!
Before proceeding, disconnect the power from the power
supply cable. Ensure that the voltage of the unit matches the
voltage and type of the power supply being used.