DINION capture 5000 IP

Safety en 13

 

 

Environmental statement - Bosch has a strong commitment towards the environment. This unit has been designed to respect the environment as much as possible. Electrostatic-sensitive device - Use proper CMOS/MOS-FET handling precautions to avoid electrostatic discharge.

NOTE: Wear required grounded wrist straps and observe proper ESD safety precautions when handling the electrostatic- sensitive printed circuit boards.

Fuse rating - For protection of the device, the branch circuit protection must be secured with a maximum fuse rating of 16A. This must be in accordance with NEC800 (CEC Section 60). Moving - Disconnect the power before moving the unit. Move the unit with care. Excessive force or shock may damage the unit.

Outdoor signals - The installation for outdoor signals, especially regarding clearance from power and lightning conductors and transient protection, must be in accordance with NEC725 and NEC800 (CEC Rule 16-224and CEC Section 60).

Permanently connected equipment - Incorporate a readily accessible disconnect device external to the equipment. Pluggable equipment - Install the socket outlet near the equipment so it is easily accessible.

PoE Plus - Use only approved PoE Plus devices.

By default, power is supplied to the camera via the standard (11-30 VDC or 24 VAC) power connection. If connection is made via the Ethernet cable, compliant with the Power-over- Ethernet (IEEE 802.3at Type 2) standard at the same time as the standard connection, the standard connection will prevail without damage to the device. To use PoE Plus, standard power must be turned off.

Bosch Security Systems, Inc.

Installation Manual

1.0 2012.01

Page 13
Image 13
Bosch Appliances installation manual Dinion capture 5000 IP Safety en