24 en Installing the DINION capture

DINION capture 5000 IP

 

 

NOTICE!

For purposes of evaluation and testing of the mounting bracket's integrity under static loading at CSA, the unit was mounted to a drywall surface as per the procedures below:

Locate a stud in the wall and mark the outside edges of the stud.

Using the wall mount bracket as a template, align the mounting hole with the center of the stud.

Mark the point on the wall in the center of the hole where

the mounting bolt will be positioned.

Remove the wall mount bracket and drill a pilot hole at the marked point.

Align the wall mount bracket mounting hole with the hole drilled in the wall.

Using a screwdriver, secure the wall mount bracket by screwing a 2.5 in. screw with washer securely into the stud.

Follow this procedure to attach the three remaining screws.

NOTICE!

The camera has not been evaluated for safety requirements using other mounting kits.

3.4Preparing the Wiring

CAUTION!

Before proceeding, disconnect the power from the power supply cable. Ensure that the voltage of the unit matches the voltage and type of the power supply being used.

The DINION capture 5000 IP is pre-wired with a 2-m long power input lead and 10/100 Ethernet cable with a male RJ45 connection. The DINION capture 5000 IP can accept power via the Ethernet cable compliant with the Power-over-Ethernet+ (PoE+ IEEE 802.3at) standard or from a Class 2 power supply.

1.0 2012.01

Installation Manual

Bosch Security Systems, Inc.

Page 24
Image 24
Bosch Appliances 5000 IP installation manual Preparing the Wiring