Conettix Communications Receiver/ | Card Functions and Locations en 15 | |
Gateway | ||
| ||
|
|
X |
Table 5.1: Power LED Indications
The figure below shows and defines the D6600/D6100IPv6 System Trouble LEDs.
System Trouble LED Status
Solid Red or Yellow | Clear |
No System Trouble
Any System Trouble*
*Refer to Appendix B: D6600/D6100IPv6 Internal Messages in the D6600/D6100IPv6 Computer Interface Manual (P/N: 4998122703). The following items cause system trouble. The items indicated by ** can be enabled or disabled. If they are disabled, they will not cause a system trouble condition.
Battery Missing**
UPS AC Fail**
Battery Bad**
UPS Battery Low**
AC Fail
System Temperature High
External Printing Error**
Line Fault**
COM# Error**
Line Card Trouble**
COM3 Trouble**
| Table 5.2: System Trouble LED |
|
|
5.2 | Line Cards and Modules |
| |
|
|
|
|
| Name | Model | Description |
|
|
|
|
| Telephone line card | D6640 | Legacy Card: |
|
|
| Up to eight line cards can be installed in |
|
|
| one D6600 Receiver, for up to 32 |
|
|
| telephone line connections. |
|
|
|
|
| Telephone line card | D6641 | Functions like the D6640. Includes |
|
|
| improved Public Switched Telephone |
|
|
| Network (PSTN) processing, additional |
|
|
| memory for future enhancements such as |
|
|
| VoIP Compensation, and single firmware |
|
|
| upgrade package. |
|
|
|
|
| CPU card | D6610 | The D6600 uses one CPU card. The CPU |
|
|
| card takes the incoming information from |
|
|
| the line card and routes the information |
|
|
| to an automation port, the LCD on the |
|
|
| front of the receiver, and an external |
|
|
| printer. |
|
|
|
|
|
|
|
|
Bosch Security Systems, Inc. | Installation and Operation Guide | 2012.11 08 4998122704 |