80 en Specifications | Conettix Communications Receiver/ | |
Gateway | ||
| ||
|
|
17 | Specifications |
|
|
| |||
|
|
|
|
|
|
| |
Dimensions |
| D6600 | Rack mount (4U) | 18 cm x 48.3 cm x 49.5 cm |
| ||
(H x W x D) |
|
|
|
|
| (7.0 in x 19.0 in x 19.5 in) |
|
|
|
|
|
|
|
|
|
|
|
| Standalone |
| 18 cm x 45.0 cm x 49.5 cm |
| |
|
|
|
|
|
| (7.0 in x 17.75 i. x 19.5 in) |
|
|
|
|
|
|
|
| |
|
| D6100IPv6 | Rack mount (2U) | 9.0 cm. x 37.5 cm. x 25.5 cm |
| ||
|
|
|
|
|
| (3.5 in x 19 in x 10 in) |
|
|
|
|
|
|
|
|
|
|
|
| Standalone |
| 9.0 cm. x 30.5 cm. x 25.5 cm |
| |
|
|
|
|
|
| (3.5 in x 12.0 in x 10 in) |
|
|
|
|
|
|
|
|
|
Weight |
| D6600 | 8.7 kg (19 lb) |
|
|
| |
|
|
|
|
|
|
|
|
|
| D6100IPv6 | 3 kg (7 lb) |
|
|
| |
|
|
|
|
|
|
| |
|
| AC Nominal Operating |
| 120 V or 230 V |
| ||
|
| Range |
|
|
|
|
|
|
|
|
|
|
| ||
|
| AC Maximum Operating |
| 100 VAC to 120 VAC, 220 VAC to 240 VAC, 50 - 60 Hz | |||
|
| Range |
|
| 2.5 A maximum |
| |
|
|
|
|
|
|
| |
|
| Power Cord |
|
| IEC 60320 C13 type |
| |
|
|
|
|
|
| ||
|
| Replaceable Fuse |
| 2.5A F250V fast blow 5x20mm |
| ||
|
|
|
|
| |||
D6100IPv6 Power Input | AC Nominal Operating |
| 18VAC (see specific Installation Supplement supplied | ||||
|
| Range |
|
| with your product for your application for supplied | ||
|
|
|
|
| transformer specifics) |
| |
|
|
|
|
|
| ||
Current Required |
| D6600 with one line card |
| Required battery current | 800 mA | ||
|
| installed |
|
|
|
|
|
|
|
|
| Required UPS AC standby current | 350 mA | ||
|
|
|
|
| |||
|
|
|
|
|
| ||
|
| For each additional line card |
| Required additional battery current | 210 mA | ||
|
| or terminal card pair |
|
|
|
| |
|
|
| Required additional UPS AC | 35 mA | |||
|
|
|
|
| |||
|
|
|
|
| standby current |
| |
|
|
|
|
|
|
| |
|
| For network |
|
| Required additional battery current | 10 mA | |
|
| communications card |
|
|
|
| |
|
|
| Required additional UPS AC | 10 mA | |||
|
|
|
|
| |||
|
|
|
|
| standby current |
| |
|
|
|
|
|
|
| |
|
| D6100IPv6 |
|
| Required battery current | 330 mA | |
|
|
|
|
|
|
| |
|
|
|
|
| Required UPS AC standby current | 250 mA | |
|
|
|
|
| |||
Standby Power |
| The receiver includes an external battery connection and battery harness. Use 12 V | |||||
|
| rechargeable sealed |
| ||||
|
| Standby power supply (UPS or battery) requirements: | |||||
|
| applications (UL864); 4‑hour minimum for UL Burglary applications (UL1610). | |||||
|
| Refer to Connecting External Batteries, page 27 for battery size. |
| ||||
|
|
|
| ||||