78 en Troubleshooting Guide | Conettix Communications Receiver/ | |
Gateway | ||
| ||
|
|
D6200 cannot connect to the D6600/ D6100IPv6.
D6200 serial connection is defective, missing, or incorrect serial cable.
Ensure that the cable between the PC and the D6600/D6100IPv6 is
Ensure that the
On the D6600, ensure that Menu Item 4.5.9
If upgrading software, ensure that Menu Item 4.5.7 Software Programming Enable (on the D6600/D6100IPv6) is set to 1.
Notice! If Software Programming Enable is set to zero (0), communication between the D6200 and the D6600 is successful but the upgrades fail.
If using COM4 through a direct connection, check that Menu Item 6.1.5 COM4 Network Adapter is set to 0.
If using COM1 through a direct connection, check that Menu Item 6.2.5 COM1 Network Adapter is set to 0.
Port conflicts with other applications on the host PC.
Reboot the PC and restart the D6200 with no other applications running.
Defective CPU terminator card. Defective CPU card.
Defective PC COM port.