Conettix Communications Receiver/ | Network Communications en 53 | |
Gateway | ||
| ||
|
|
12.2.3Conettix Datagram Type Differences
| Notice! | |
i | Install software version 5.5C or later in the network device | |
D6680) for the Datagram Type Function. | ||
| ||
| Software version 1.5D or later must be installed in the DX4020 or C900V2. | |
|
| |
|
|
i | Notice! | |
If you are using a D6686 or D6100IPv6, the datagram section does not apply to the receiver | ||
| configuration. | |
|
| |
| Datagram 02 | |
| This datagram uses the IP address and the port number to identify and ACK packets from the | |
| receiver to the field devices which allow multiple devices to be installed behind a single | |
| outgoing IP address. This datagram type requires that CPU version 01.02.01 or later is | |
| installed, and that receiver parameter 6.8.6 is programmed as 1. | |
| To use this datagram type, program it in the following order: | |
| 1. | Confirm that D6200 version 1.20 or later is installed. |
| 2. | Confirm that the D6600 CPU version 01.02.01 is loaded in the receiver. |
| 3. | With the D6200 software, select Network → Network Configuration Management → |
|
| Read/Manage Network Configuration from Receiver. |
| 4. | Select the 6.8 Global Parameters tab. |
| 5. | Change the 6.8.6 6600 Datagram Type value to 1. |
| 6. | Send the changes to the receiver and close the window. |
| 7. | Select Network → Network Utilities → Network Device Setup and select the Telnet to |
|
| Device tab. |
| 8. | Type or find the IP address of the D6680/D6682 in the list and establish a telnet session |
|
| with the D6680/D6682. |
| 9. | After establishing the telnet session, select the channel(s) to use by pressing [1] or [2], |
|
| and then press Enter. |
| 10. | Press Enter until you have selected Datagram and type 02, then press Enter, If both |
|
| channels are used, change both channels. |
| 11. | Save the settings and exit from the D6680/D6682 setup. |
| Datagram 07 | |
|
| |
i | Notice! | |
This datagram is supported only on the E2‑RAD version of the | ||
| Module. | |
|
| |
| This datagram type is used only in the NIM of the network device | |
| The datagram type allows the Source and Destination ports to be set independently. This use | |
| of a different source port allows NAT (Network Address Translation) tables of routers or | |
| firewalls to direct packets to the correct NIM of the field device. | |
| To use this datagram type, program in the following order: | |
| 1. | Telnet to the NIM of the field device as described in the appropriate network device |
|
| |
| 2. | Select channel 1 of the NIM. |