Bosch Appliances D6600 Callout ᅳ Description, ᅳ Bosch Control Panels

Models: D6600

1 88
Download 88 pages 54.03 Kb
Page 44
Image 44
ᅳ Bosch Control Panels

44 en Network Communications

Conettix Communications Receiver/

Gateway

 

 

 

23

4

1

5

1 2 4 8

11 15

14

10

12

11

 

 

13

6

7

8

9

Figure 12.2: Conettix Network System Connection diagram – D9133TTL-E/DX4020 and Bosch Control Panels

Callout Description

Callout Description

 

 

 

1

ᅳ Bosch Control Panels

9 ᅳ D6100IPv6

 

 

 

 

2

ᅳ Connection – control panel serial device

10

ᅳ Connection – Ethernet hub to

interface (SDI) bus to D9133TTL-E or DX4020

Network Ethernet Module

bus terminals

 

 

 

 

 

 

3

D9133TTL-E or DX4020 Network Interface

11

ᅳ Network Ethernet Module

Module

 

 

 

 

 

4ᅳ Connection – D9133TTL-E or DX4020

12

ᅳ Connection – Network Ethernet

Ethernet port to Ethernet hub

Module to D6600 COM4 port

 

 

 

 

5

ᅳ Host PC running D6200 Programming

13

ᅳ D6600

Administrative Software

 

 

 

 

 

 

6

ᅳ Connection – Ethernet hub to Host PC

14

ᅳ Connection – second Network

NIC

Ethernet Module to D6600 COM 1 port

 

 

(optional)

 

 

 

 

2012.11 08 4998122704

Installation and Operation Guide

Bosch Security Systems, Inc.

Page 44
Image 44