Bosch Appliances D6600 11.4.5Software Version Display, 11.4.6Keypad Functions, Line Test Function

Models: D6600

1 88
Download 88 pages 54.03 Kb
Page 37
Image 37
11.4.5Software Version Display

Conettix Communications Receiver/

D6600/D6100IPv6 Operation en 37

Gateway

 

 

 

As you correct system troubles, the receiver removes them from this list. The system trouble light is no longer illuminated. Refer to Troubleshooting Guide, page 77 for more information.

11.4.5Software Version Display

The software version display indicated the current software versions of the CPU and each line card.

11.4.6Keypad Functions

Use keypad functions to quickly and easily access certain features and run commands, or functions, from the keypad.

Accessing functions:

1.Press the Function key.

2.Enter your password.

i

Notice!

D6600 default password: 6600

 

D6100IPv6 default password: 6100

3.Press the Enter key to go to the Welcome Manager.

4.Press the number key for the function you wish to run. For example, press the [1] key.

5.Press the Enter key. The function runs.

Communication Links Test (Function 1)

Use this function to test the communication links to the automation firmware and printer. Running the Communication Links Test function:

1.Press the Function key.

2.Enter your password and press the Enter key to go to the Welcome Manager.

3.Press [1] and Enter.

Communication Links Test Outputs

Printer

DD/DDsTT:TTsL08sACCTs888sss

 

[TEST]s2Nsss8

 

 

Automation

6500 Mode h1rr8sssssss888s[sss8t

 

SIA Mode <header>[NVX]

 

 

Skip Current Automation Event (Function 2)

Use this option to skip the current Automation event.

Running the Skip Current Automation function:

1.Press the Function key. Enter your password and press the Enter key to go to the Welcome Manager.

2.Press [2] and Enter.

Line Test (Function 3)

Use this option to test the line operation.

Running the Line Test function:

1.Press the Function key. Enter your password and press the Enter key to go to the Welcome Manager.

2.Press [3] and Enter.

3.Press the number key for the line you wish to test. The line disconnects, the receiver sends the handshakes, and the line reconnects.

Bosch Security Systems, Inc.

Installation and Operation Guide

2012.11 08 4998122704

Page 37
Image 37