MIC412TI and MIC412TF Camera | Installation and Operation Manual AAA EN | 31
Bosch Security Systems Issue 8
Self Diagnosis
This function is for future products and does not work with the MIC400 or MIC412.
Default Settings
The Default Settings tab reads and sets settings from the following sections:
- Manual Control Auxiliaries
- General Settings
- Auto Home Controls
- Multi Alarm Settings
- Lens Recalibration
- Frame Integration Settings
- All Thermal controls
All other settings will not be saved, loaded, downloaded or set through the
following controls.
Get Current MIC Settings
This downloads the current status of each of the settings from the MIC and loads it
into the text boxes and radio buttons on Camset. This provides an easy way of
viewing the current setup of each MIC and also a way of copying the settings from
one into the next.
Save Current MIC Settings
This option will first prompt for a file location and then store the current state of all
the options outlined above to an XML file which can then be loaded at a later date
back into Camset as a standard for a specific site.
Load Settings into Camset
This will prompt to open an XML file as saved above. Only valid Camset Default
XML files will work.
Set Current Settings to MIC
This will go through each of the settings above except for thermal, and send out
the commands to the MIC to set it up as Camset displays. This may take a few
seconds as there are several commands involved in this process.
Upload Default Options
At the end of this there are 2 extra options for defaults, Clear SS and NDZ will
clear any saved Soft Stops and Non-Dwell Zones and then Find End Stops. These
options may be used to completely set up a MIC after it has been reprogrammed
to a new protocol.