MIC412TI and MIC412TF Camera Installation and Operation Manual

Configure MIC Communications

This button opens up a new window which provides the options to reconfigure the MIC communications settings. These options will depend on the MIC model connected.

In order for any of these modifications to work, Camset must have full communications with the MIC. Ensure this by performing a simple manual control test (Up, Down, etc). To store the new settings press Apply once the modifications have been made or alternatively press Cancel to discard any changes.

New Address

This input box defines the new address the MIC should change to once Apply has been clicked. The value will also be copied over into Current Address on the main form to provide continual control.

New Protocol

The drop down list here provides a full list of the protocols available in Camset. Control depends upon selecting the correct protocol in the drop down list to match the protocol that is loaded onto the MIC412; if the incorrect protocol is selected in Camset the MIC may not respond. To regain control should this happen, reset the Camset Protocol back to what the MIC originally was.

EN 24

New Baud Rate

This drop down list will provide the valid baud rates for the chosen protocol. The baud rate options reflect the protocol as set on the main form for Camset itself. In FV protocol the option is a toggle which simply switches the MIC between 4800 and 9600. If control is not present after the window is closed, try changing the Camset Baud Rate.

Reset MIC

This sends out a command to reboot the software. This is not a hardware reboot; the only way to do that is to remove the power supply to the MIC.

Camset Settings

The Camset Settings section as shown above control the Protocol, MIC model, Baud Rate and Comm Port used; select the appropriate parameters for your MIC400 from the dropdown menus.

Some functions in Universal Camset may not be supported by particular protocols; any incompatible functions will be greyed out if it is not supported in a given protocol.

The communication settings will be set to the default for the chosen protocol, indicating this on the Camset Baud Rate drop down list.

Bosch Security Systems

Issue 8

Page 24
Image 24
Bosch Appliances MIC412 operation manual Camset Settings