MIC Programmer
The MIC programmer allows users to change the protocol of the MIC400 camera
unit; you must have the protocol file (.MOT) you wish to upload available, these are
available on the CD with the MIC412 or from the Bosch Security Systems.
To change a protocol loaded into a MIC400 please do the following:-
1. Connect the MIC400 to a PC running Universal Camset as described on
page 27, check the MIC400 is communicating correctly with Camset; this
can be checked using the Comms function.
2. Use the Browse button to locate the new .MOT file you wish to upload to
the MIC400.
3. In the Security Code section, enter the MIC serial number in the
appropriate field; click the Generate Security Code button. The security
code will now be created.
CAUTION: Ensure you have the correct version and software for
your MIC400. Uploading the wrong software may cause the
MIC400 to function incorrectly. If you are unsure of which
version you require, please contact Bosch Security Systems.