Set Mask Type

If Crosshair and Mask Style are both turned On this function can be used to step through each of the available mask types one at a time. This will not update all the masks to the same type, only the ones that are created subsequent to the change.

Load Factory Defaults

Resets the privacy card to the factory defaults.

MIC Configuration

These options define the MIC's orientation, which defines how the masks track. for Inverted MICs, the head would normally be rolled around through 180 degrees, with Pan Reverse On to regain sensible control. However, with inverted IR MICs, the head cannot be rotated around due to the IR Lamp arms, and therefore the video must be inverted, and both controls reversed.

Basic Calibration

This sends a set of default commands to the MIC to initialize the privacy for an upright MIC. This will not be perfect as each board needs fine individual calibration but provides a good starting point.

Zoom Alignment

The zoom alignment buttons provide accurate calibration of the mask tracking. This would normally be carried out by using a vertical line of mask on along a known straight edge. If this line then moves as the MIC pans and tilts, it can be corrected using the appropriate arrow. The labels indicate the current value in both the Vertical and Horizontal planes, which will be incremented or decremented dependant upon the direction pressed.

Direct Command

All privacy commands consist of 2 Hex bytes, a command byte and a data byte. These perform all of the privacy functions available. To enter commands, enter the 2 bytes in Hex, into the boxes provided and press Send Command. Entering random commands here may result in very odd results so please do not use unless under specific instruction.

Save Current Settings

EN 34

Once any calibration changes are made, this button should be pressed to save the new values permanently.

Privacy Calibration

CAUTION: The Privacy Calibration settings should be configured at manufacture and should therefore not need to be changed on site.

Any changes to these settings may be difficult to correct, so please do not attempt to change anything unless under instruction from Bosch.

The Privacy Calibration section deals with the calibration settings of the privacy masking. I.e. how the masks track as the MIC is moved in Pan, Tilt or Zoom.

MIC Configuration

These options define the MIC's orientation, which defines how the masks track. for Inverted MICs, the head would normally be rolled around through 180 degrees, with Pan Reverse On to regain sensible control. However, with inverted IR MICs, the head cannot be rotated around due to the IR Lamp arms, and therefore the video must be inverted, and both controls reversed.

Basic Calibration

This sends a set of default commands to the MIC to initialize the privacy for an upright MIC. This will not be perfect as each board needs fine individual calibration but provides a good starting point.

Zoom Alignment

The zoom alignment buttons provide accurate calibration of the mask tracking. This would normally be carried out by using a vertical line of mask on along a known straight edge. If this line then moves as the MIC pans and tilts, it can be corrected using the appropriate arrow. The labels indicate the current value in both the Vertical and Horizontal planes, which will be incremented or decremented dependant upon the direction pressed.

Direct Command

Bosch Security Systems