Brocade Adapters Administrator’s Guide 187
53-1001256-01
port B
bcu port --name 1/0 emc_fab3_ad5_p0
Port 1/0’s name set to emc_fab3_ad5_p0
bcu port --name 1/0
Port 1/0’s name is emc_fab3_ad5_p0
bcu port --enable 2/1
port enabled
bcu port --enable 2/1
port is already enabled
bcu port --disable 2/1
port disabled
bcu port --disable 2/1
port is already disabled
bcu port --stats 4/0
tx_frames: 4096
tx_words: 202448224
rx_frames: 1024
rx_words: 10224844
lip_count: 2096
nos_count: 64
error_frames: 2
dropped_frames: 12
link_failures: 6
loss_of_syncs: 2
loss_of_signals: 8
primseq_errs: 2
invalid_tx_words: 4
invalid_crcs: 32
bcu port --statsclr dell_s1_ad0_p1
port stats cleared
bcu port --query 1/0
port id: 1/0
port type: CNA
port instance: 0
port name:
Media: sw
Speed: 10G
CNA/CEE status: CEE Linkup
FCoE:
MAC: 00:05:1e:8e:b6:02
pwwn: 10:00:00:05:1e:8e:b6:02
nwwn: 20:00:00:05:1e:8e:b6:02
state: Linkup
Topology:
current: P2P
configured: P2P
SNIA port type: N
supported classes: Class-3
symbolic name: BR-1020 | 2.0.0.0 | | |
maximum frame size: 2112
receive bb credits: 48
transmit bb credits: 74
QOS: Disabled