Brocade Adapters Administrator’s Guide 81
53-1001256-01
CEE properties panel (CNA only) A
CEE properties panel (CNA only)
The CEE properties panel enables you to display the properties that are associated with a selected
converged network adapter (CNA).
Operational CEE Configuration is displayed when the CEE Status is Active. The Remote CEE
Configuration table is visible only when the CEE status is inactive and error reason is not one of the
following.
CEE_PHY_LINK_DOWN
CEE_LLDP_SHUTDOWN_TLV_RCVD
CEE_PROTOCOL_INIT
CEE_LLDP_INFO_AGED_OUT
Opening the dialog box
1. Select a CNA in the device tree.
2. Click the CEE tab in the right pane.
Fields and components
Field Description
FCoE Logical Link Status The operational status of the FCoE logical link; for example, Up or
Down.
DCBCXP Version The DCBCXP version type; for example, CEE.
Priority Group ID The priority group ID. Values are 0-7 and 15 (strict priority). When
coupled with bandwidth percentage and CoS, you can manage
traffic by grouping like traffic together and giving each type a
different priority level.
% Bandwidth The bandwidth percentage for a given priority group.
Priority Flow Control Indicates whether priority flow control is turned on or off.
Ethernet Link Layer Specifi es a priority value between 0 (signifying best effort) and 7
(signifying real-time data) to differentiate traffic.
FCoE CoS The Fibre Channel Class of Service that specifies a priority value.