64 Brocade Adapters Administrator’s Guide
53-1001256-01
Fibre Channel diagnostics using the GUI
6
3. Click the check box that corresponds to the port test you are running.
4. Specify the parameters based on parameter information found in Table 15.
NOTE
Click the Stop on Error check box if you want the test to stop running if an error occurs.
5. Click Start to run the test.
Hardware-level test parametersTABLE 15 Hardware-level test parameters
Hardware-level test Parameter Test Options
Memory test
NOTE: During the test IOC will
be disabled.
None You can enable or disable this test.
Regardless of test cycle set value, the
Memory Test will run only once.
PCI loopback test Frame Count Integer from 0 - 4,294,967,295. The
default value is 8192.
Data Pattern Default value is A5A5A5A5.
Test Cycle The number of times the test runs. The
default value is 10.
Port loopback test
NOTE: For an External
Loopback test, you must plug
in the loopback connector.
Subtest ID •External
•Serdes
Link Speed 10 Gbps
Frame Count Integer from 0 - 4,294,967,295. The
default value is 8192.
Test Cycle The number of times the test runs. The
default value is 10.
Data Pattern (hexadecimal) Default value is A5A5A5A5.