CHAPTER 4 CONTROL PANEL

CONTINUE MODE

If any recoverable error occurs, including “Toner Empty,” it can be cleared with the Continue button. The Continue button function is selected with this mode setting.

Display Message

Continue Mode

CONTINUE=MANUAL

Select the manual error recovery mode. Press

 

the Continue button to clear errors.

 

(Factory setting)

 

 

CONTINUE=AUTO

Select the auto error recovery mode. The

 

printer automatically clears recoverable

 

errors. You need not press the Continue

 

button.

SCALABLE FONT

 

Note

The setting in this mode menu is effective only in the HP PCL5C mode. It does not appear in any other emulation modes.

Since this printer has many scalable fonts, some application programs may not be able to handle them correctly. When the HP PCL5C emulation mode has been selected, the printer may print a different font rather than the font you have selected with your program or a font selection command.

To cope with this font problem, you can restrict the font selection by using this setting as follows:

Display Message

Scalable Font

 

 

FONT=ALL

All scalable fonts for this printer can be

 

selected with the font selection command.

 

(Factory setting)

FONT=LJ

Scalable fonts for this printer other than the

 

following can be selected with the font

 

selection command: Atlanta, Bermuda

 

Script, PC Brussels, Copenhagen, Germany,

 

Portugal, Calgary, San Diego, and US

 

Roman.

Even if you restrict the font selection as above, you can select among all the scalable fonts with the Font button. The setting in this mode menu merely restricts the font selection command from an application to avoid incorrect font selections.

4–45