Appendix B: Image File Download Using OIDs
•Enter the IP address of the TFTP server in standard dotted decimal notation (e.g., 132.177.118.24).
•Enter the FULL path to the image file in the ctDLTFTPRequest OID, including the name of the image file (e.g., c:\tftpboot\sehi.hex).
Table B-1 OIDs and Settings
Step | OID Name | OID Number | Data | SNMP OID | |
Type | Data | ||||
|
|
| |||
|
|
|
|
| |
|
|
|
|
| |
1. | ctDLForceOnBoot | 1.3.6.1.4.1.52.4.1.5.8.1.1.0 | integer | 1 | |
|
|
|
|
| |
2. | ctDLCommitRAMToFlash | 1.3.6.1.4.1.52.4.1.5.8.1.2.0 | integer | 1 | |
|
|
|
|
| |
3. | ctDLTFTPRequestHost | 1.3.6.1.4.1.52.4.1.5.8.1.4.0 | IP | Enter the IP | |
|
|
| address | address of | |
|
|
|
| the TFTP | |
|
|
|
| server. | |
|
|
|
|
| |
4. | ctDLTFTPRequest | 1.3.6.1.4.1.52.4.1.5.8.1.5.0 | string | Enter the | |
|
|
| (ASCII) | path to the | |
|
|
|
| image file. | |
|
|
|
|
| |
5. | ctDLInitiateColdBoot | 1.3.6.1.4.1.52.4.1.5.8.1.3.0 | integer | 1 | |
|
|
|
|
|