Fiber Optic TPIM Specifications

RX

TX

LNK

 

 

 

 

TPIM-F2

Figure A-3. The TPIM-F2 Faceplate.

A.3.1 TPIM-F2 for Multimode Fiber

The TPIM-F2 connector supports Multimode Fiber Optic Cabling. Table A-2. TPIM-F2 Specifications.

Parameter

Typical

Worst Case

Worst Case

Typical

Value

Budget

Budget

 

 

 

 

 

 

 

 

 

 

 

 

Receive

-30.5 dBm

-28.0 dBm

Sensitivity

 

 

 

 

 

 

 

 

 

Peak Input

-7.6 dBm

-8.2 dBm

Power

 

 

 

 

 

 

 

 

 

 

Transmitter Power:

 

 

 

 

 

 

 

50/125 m

-13.0 dBm

-15.0 dBm

13.0 dB

17.5 dB

 

 

 

 

 

62.5/125 m

-10.0 dBm

-12.0 dBm

16.0 dB

20.5 dB

 

 

 

 

 

100/140 m

-7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

 

 

 

 

 

Error Rate: Better than 10-10

The transmitter power and receive sensitivity levels given in Table A-2 are Peak Power Levels after optical overshoot. A Peak Power Meter must be used to correctly compare the given values to those measured on any particular port. If Power Levels are being measured with an Average Power Meter, then 3 dBm must be added to the measurement to correctly compare those measured values to the values listed in Table A-2 (i.e. -30.5 dBm peak=-33.5 dBm average).

Page A-3

Page 70
Image 70
Cabletron Systems STHI manual TPIM-F2 for Multimode Fiber, Parameter Typical Worst Case, Budget