Cabletron Systems STHI manual The Chassis Status View Screen, OPERATIONAL Mode

Models: STHI

1 77
Download 77 pages 20.09 Kb
Page 54
Image 54
OPERATIONAL Mode

The Chassis Status View Screen

OPERATIONAL Mode

3

In OPERATIONAL mode (Figure 5-7), the Chassis Status View screen is read-only, displaying the operational status of all ports throughout the stack. The possible states for Ring ports differ from those for STN TCUs.

STHI LOCAL MANAGEMENT

 

 

Flash Image Version: 1.00.00

 

CHASSIS STATUS VIEW (

OPERATIONAL

)

 

 

 

 

5

 

4

 

3

 

2

 

1

 

STH24

 

STH24

 

STH24

 

STH24

STHI24

 

--->

 

<--->

 

<-B->

 

<--->

 

<---

 

16Mb/s

 

16Mb/s

 

16Mb/s

 

16Mb/s

16Mb/s

1

BYP

1

BYP

1

BYP

1

BYP

1

INS

2

INS

2

INS

2

LNK

2

BYP

2

INS

3

ENB

3

LNK

3

ENB

3

ENB

3

INS

4

INS

4

LNK

4

INS

4

LNK

4

INS

5

LNK

5

INS

5

INS

5

LNK

5

INS

6

INS

6

INS

6

ENB

6

LNK

6

ENB

7

ENB

7

ENB

7

ENB

7

ENB

7

ENB

8

ENB

8

ENB

8

ENB

8

ENB

8

ENB

9

INS

9

INS

9

ENB

9

INS

9

ENB

10

INS

10

INS

10

INS

10

INS

10

BYP

11

INS

11

INS

11

INS

11

INS

11

LNK

12

ENB

12

ENB

12

ENB

12

INS

12

ENB

NEXT

[

OPERATIONAL

 

] [ REFRESH 3sec ]

RETURN

Figure 5-10. Chassis Status View Screen in OPERATIONAL Mode

Each Ring port (TPIM port or Ring Out TCU) may be listed as:

ACT The enabled ring port has opened its connection, having detected data on the line. The attached device is inserted into a ring.

WRP The port is in the wrap state. Either the port is disabled, or is not detecting data and is remaining closed.

Each station TCU port may be listed as:

INS The port is enabled and the attached device is applying phantom current. The device is inserted into the ring.

ENB The port is enabled but no phantom current is present.

BYP The port is disabled (see ADMINISTRATIVE mode) and no phantom current is present.

LNK An attached device is applying phantom current, but the port is disabled, preventing insertion of the attached device into the ring.

Page 5-19

Page 54
Image 54
Cabletron Systems STHI manual The Chassis Status View Screen, OPERATIONAL Mode, Each station TCU port may be listed as